Mumbai

Stand Mounted Axial Fan

Axial Fan by Vayuvents

Stand Mounted Axial Fan

Phone Number

Email Address sales@vayuvents.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Ground Floor, Shop No - 38, S.No - 48/A, Viva Complex, Building No - 2, Near Shalimar Hotel, Waliv, Vasai East, Mumbai, Ground Floor, Shop No - 38, S.No - 48/A, Viva Complex, Building No - 2, Near Shalimar Hotel, Waliv, Vasai East, Mumbai

Mumbai, India, 401208

Description

Product Description we manufacture and supply supreme quality Exhaust Flow Fan that is used for moving air where the temperature is either hot or cold. The offered flow fan is designed and manufactured by our technical experts using superior grade components and modern techniques to meet the design guidelines as per the international authorities. Further, this Exhaust Flow Fan is available in numerous technical specifications as per the specific application requirements of our clients. Impeller The impellers of the vayuvents fan are tested for simulated aerodynamic loads, load deflection characteristics and the strain at the shank. vayuvents Impellers usually have blades with cross-sections matching those of an aerofoil. As compared to curved sheet blades, aerofoil can apply greater force to the air, thereby increasing maximum pressure and can maintain better efficiency over a wider range of volumetric flow. Also by increasing the thickness & curvature of the inner sections, the blades can be made stiffer; this limits flutter and allows the impellers to run at higher speeds. Construction: Casing The casing encloses the impeller and motor assembly completely. vayuvents axial flow fan casings are generally rolled and flanged from heavy-gauge mild steel. Flameproof and increased-safety motors are not normally placed outside the casing and can be connected directly to the terminal box in accordance with the requirements for the particular hazardous zone. Hub The design of vayuvents fan impeller and hub is based on the worst possible aerodynamic load and centrifugal load scenario. The hub incorporates a system for the adjustment of pitch angle, cleaning or repair of the impellers. Fixings All impellers are assembled together using high-tensile, zinc-plated bolts and self- locking nuts. Balancing The balance of impeller assembly complete with the hub is carefully checked to ensure vibration-free running. Both the static & dynamic balance tests are carried out before testing the fan for its performance. Pitch Adjustment The blades of vayuvents axial-flow fans are often attached to the hubs by a system which allows the pitch angle to be set at any desired value on assembly. This adjustment pitch feature enables the fan to be supplied preset for exactly the volume flow required, eliminating the waste of power. Tip Clearance vayuvents fan impellers are generally mounted on the shaft extension of the driving system. This is supported in a cylindrical casing surrounding the impeller with the minimum practical running clearance; a typical value for this radial clearance is 0.25% of the impeller diameter. Fan Driving Systems The fan assembly could be mounted on a wide range of driving systems to meet the desired range of performances and applications. These includes the following: Direct-drive In this case, the fan is directly mounted on the motor shaft inside the casing. Belt drive The belt-driven units are employed for applications where the motor must be placed out of the air stream. Generally, V-belt belts are used by us as the connecting medium. Fan Performance The way vayuvents fan impellers (blades or rotors) are designed, the amount of air they can move decreases as the pressure they are working against increases. The airflow vs. pressure information for a particular fan is called the fan performance data. The performance of a fan depends on the size, shape & speed of the impeller. The fan performance data is essential for selecting fans as per the desired airflow and system pressure. Fan Performance Curves Fan performance curves and data show how much pressure and airflow a given fan can produce at a given speed. This data is based on the system resistance (pressure) occurring away from the fan. Fan performance curves are developed by fan manufacturers based on the testing of a prototype fan fabricated based on the theoretical design. Applications The vayuvents axial flow fans are widely used for providing the required airflow for heat & mass transfer operations in various industrial equipment and processes. These include cooling towers for air-conditioning & ventilation, humidifiers in textile mills, air-heat exchangers for various chemical processes, ventilation & exhaust as in mining industry etc. All the major industries use large number of axial flow fans for operations, such as Power generation, Petroleum refining & petrochemicals, Cement, Chemicals & pharmaceuticals. Features: Compact design High durability Low power consumption Impeccable performance A fan consists of a series of radial blades/impellers attached to a central rotating hub. The rotating assembly of blades and hub comprises a fan assembly and it may or may not be enclosed in a housing. Fans are driven by an electric motor to generate airflow through a given system.

Keywords

Other Products

view all

68179d65be22ee500d53ff54 Card 2

product image
Resistor Load Bank Cooling Fan

During an electrical utility outage, mission critical facilities, such as hospitals, data center, and certain financial institutions continue to operate via emergency standby generators. The only way to verify that a backup power system will operate as designed is to periodically test it under load. Load bank tests assure facility managers that their generators will perform at 100% of their nameplate rating. A load bank applies a stable, controllable electrical load on a generator. It can be permanent or portable, can accommodate AC or DC, and can generate electrical power that ranges from a few kW to multiple MW. Even small load banks can generate a substantial amount of heat, which makes cooling a key consideration. Most load bank units have an internal fan that pushes air over the resistive load bank elements to cool them – otherwise they would burn up. A major OEM that supplies resistive load banks used to assemble its own load bank cooling ventilation systems by attaching ring fans to rectangular panel frames, mounting the motors, and assembling those components using the associated support hardware – which is a time- and labor-intensive process. An vayuvents sales rep suggested using preassembled fan units to save time and money. That was the beginning of a business relationship that has lasted nearly 10 years When the OEM realized it could save time and money, vayuvents engineers and rep worked together to satisfy the OEM’s criteria. For smaller load banks, vayuvents supplies direct drive panel (DDP) fan – many with Macheta Airfoil propellers and some with adjustable pitch backswept propellers. Most of them have 36-inch diameter propellers. Other sizes are supplied based on the OEM’s needs. The DDP fans are customized to have rectangular (instead of square) panels to fit various load bank frames. The 5-, 10-, or 15-HP panel fans have various air flow characteristics depending on the load bank model. The final destination of a load bank determines its voltage and frequency. For larger load banks, vayuvents supplies tubeaxial fans – most of them 10 HP – with the propeller on the inlet, which provides exceptional air flow over the load bank resistors. Performance is based on the number of fans that the OEM includes in the design of any given load bank. For very large load banks, vayuvents supplies direct drive Axial tubeaxial (ATA) fans because they are more compact than typical tubeaxial or vaneaxial fans. Axial propellers also provide more performance for a given diameter. These large load banks require more airflow and higher pressures than smaller units. For this application, Axial fans supply 1.7 inches WC static pressure

68179d65be22ee500d53ff54 Card 2

product image
Transformer Cooling Fan

Transformer cooling fans are sturdy, weatherproof fans for accelerating the cooling process in oil-cooled electrical transformers. They circulate air around the exterior of the transformer's radiator as oil works it way through the inside to dissipate heat and reduce the operating temperature of the transformer. Vayuvents Transformer cooling fans are sturdy, weatherproof fans for accelerating the cooling process in oil-cooled electrical transformers. They circulate air around the exterior of the transformer's radiator as oil works it way through the inside to dissipate heat and reduce the operating temperature of the transformer. These fans have a motor that rotates the fan blades to create airflow and a guard that helps protect the blades from damage and prevent injuries from accidental contact. They are typically used outdoors where most oil-cooled transformers are located.

68179d65be22ee500d53ff54 Card 2

product image
welding fume extractor

vayuvents top leading Welding Fume Extractor manufacturer in India. our Portable Welding Fume Extractor with suction arm to collect dust particles and fumes from welding process. vayuventsFume Extractor are manufactured as per the accepted quality standards. Extraction done by using 360 degree rotatable suction arm assures extract the fume easily from the welding process. Assure worker Good health and safety of human resources by removing welding smoke. Additionally, portable Welding Fume Extractor keeps product and production machines contaminant free. We give the time delivery of Portable Welding Fume Extractor at given time frame. vayuventsWelding Fume Extractor Design: vayuvents welding fume extractor is manufactured for heavy duty industrial use to capture the fume at source. Unit attached with a portable wheels frame to move wherever fume extraction is required. Fume extractor consist of 4 stage filtration with modern electrostatic filtration system. This electrostatic filtration requires periodic cleaning only. The Extractor Features four stage filtration and purification. The articulated arm with suction hood is self supporting and quickly positioned at the source of fume emission. System controlled by a control panel operated at 415 V / 50 Hz. Suitable for continuous working without any trouble. CE approved / IP 55 protection induction motor for energy efficiency. High rate of suction airflow and purifying efficiency is more than 99 % and pure air is discharge to workshop atmosphere. Fire proof Spark arrester Electronic panel board for “Filter cleaning stage” warning. Spark arrester, Multi stage filters and Electrostatic filter is easy to clean. Our Mobile Welding Fume Extractor helps to maintain pollution free atmosphere workshop