Roof Extractor fan


Vayuvents Models & Dimensions :-

Sr No
MODEL
A
B
D
C
Wight (kg)
Max Motor Frame Size
MinMax
1MRF-100-96-241800MM X 1065MM X 4MM6152004004504580
2MRF-150-96-322000MM X 1065MM X 5MM8152005005506090L
3MRF-300-96-362000MM X 1200MM X 7MM91525060065085112M


SELECTION CHART -  AXIAL FLOW FAN :-

SR No
Fan Model
Fan Dia (In mm)
Motor Rating (HP/Pole)
Motor F/S (In RPM)
Free Air (m3/hr)
Volume Flow in m3/hr at different Static Pressure in mmwg
51015202530405060708090100110
1MRF-100-96-246101.0/4144011200--11000----------
2MRF-150-96-328101.5/696017288---16800---------
3MRF-300-96-369103.0/696028110----28000--------

Note: 
1. Fan selection is based on air at 20 celcius and density 1.2 kg/m3
2. Fan performance and tolerance as per IS 3588-1987.