Mumbai
08043694712
+919096188703
Ventilation Fan by Vayuvents

Portable Ventilation Fan

Phone Number

08043694712

Please keep 0 before dialling the number.

Email Address sales@vayuvents.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Ground Floor, Shop No - 38, S.No - 48/A, Viva Complex, Building No - 2, Near Shalimar Hotel, Waliv, Vasai East, Mumbai, Ground Floor, Shop No - 38, S.No - 48/A, Viva Complex, Building No - 2, Near Shalimar Hotel, Waliv, Vasai East, Mumbai

Mumbai, India, 401208

Description

We are indulged in exporting, manufacturing, distributing and supplying the Smoke and Fume Exhauster Cum Air Blower in Ahmedabad, Gujarat, India. Fume Master is made of especially anti corrosive coated steel structure with aluminum impelled dully coated. The fume master is designed to blow or exhaust smoke or fume at very high volume and speed. The is also designed to delivery fresh air. A Strong steel structure with suitable mounting for engine / motor with lockable Castor wheels. The structure is fixed with anti-vibration pads and Swivel type wheel. VAYUVENTS Fume Exhauster Cum Air Blower is made out of special mild steel structure with heavy duty closed dynamically balanced Impeller to deliver 3000cfm of air @100mm water column ( WC) having design temperature of 20°C and operating temperature of 40°C.The Impeller is coated for anti corrosive protection from gases.The equipment is driven with a powerful Electric Motor.The Motor and Starter are of reputed make and Flame proof in nature ensuring their use even in Battery areas.The equipment has an adjustable port for varied delivery of air and is trolley mountedwith anti vibration pads and swivel type lockable castors for ease of mobility in the field.Air ventilation Blower is to be used for providing fresh air, de-smoking and gas freeing applications. Also the exhauster can be deployed for removal of fumes, gases and foul smell within the confined section or alternately for supplying fresh air via ducts within the confined section of the work zone. Operational Requirements 1. The should be Compact for ease in transportation as well as fitment The size of the fan should be 16” and all the blades should be dynamically balanced designed to provide powerful airflow 2. The Blower should also be portable and lightweight, weighing less than 20 KG (without canister, adapter and ducts). 3. Casing should be tough, double walled and made of polyethylene or superior material which is weather, chemical and dent resistant in nature. 4. The Body of the Blower should be nonmetallic to prevent rust in different environments like marine environments. Also the body MOC should be UV resistant since the blower is expected to be deployed outdoor for continuous ventilation deployment. 5. The Device should not generate high noise and the max noise level should be 80 decibels 6. It should be capable of providing High free airflow rate of minimum 3000 to 3700 CFM 7. The equipment should have simple operation with single ON/ OFF switch. Thermal Switch should be provided for overheat protection 8. The blower should be supplied along with quick couple Canister having inbuilt handle/ carrying arrangement. The Canister should be able to house the entire length of the folded duct as well as able to be fitted with the Blower on either side of discharge or suction. The quick couple canister should be attachable and detachable within 30 seconds and suitable for quick deployment.

Keywords

Other Products

view all

68179d65be22ee500d53ff54 Card 2

product image
Resistor Load Bank Cooling Fan

During an electrical utility outage, mission critical facilities, such as hospitals, data center, and certain financial institutions continue to operate via emergency standby generators. The only way to verify that a backup power system will operate as designed is to periodically test it under load. Load bank tests assure facility managers that their generators will perform at 100% of their nameplate rating. A load bank applies a stable, controllable electrical load on a generator. It can be permanent or portable, can accommodate AC or DC, and can generate electrical power that ranges from a few kW to multiple MW. Even small load banks can generate a substantial amount of heat, which makes cooling a key consideration. Most load bank units have an internal fan that pushes air over the resistive load bank elements to cool them – otherwise they would burn up. A major OEM that supplies resistive load banks used to assemble its own load bank cooling ventilation systems by attaching ring fans to rectangular panel frames, mounting the motors, and assembling those components using the associated support hardware – which is a time- and labor-intensive process. An vayuvents sales rep suggested using preassembled fan units to save time and money. That was the beginning of a business relationship that has lasted nearly 10 years When the OEM realized it could save time and money, vayuvents engineers and rep worked together to satisfy the OEM’s criteria. For smaller load banks, vayuvents supplies direct drive panel (DDP) fan – many with Macheta Airfoil propellers and some with adjustable pitch backswept propellers. Most of them have 36-inch diameter propellers. Other sizes are supplied based on the OEM’s needs. The DDP fans are customized to have rectangular (instead of square) panels to fit various load bank frames. The 5-, 10-, or 15-HP panel fans have various air flow characteristics depending on the load bank model. The final destination of a load bank determines its voltage and frequency. For larger load banks, vayuvents supplies tubeaxial fans – most of them 10 HP – with the propeller on the inlet, which provides exceptional air flow over the load bank resistors. Performance is based on the number of fans that the OEM includes in the design of any given load bank. For very large load banks, vayuvents supplies direct drive Axial tubeaxial (ATA) fans because they are more compact than typical tubeaxial or vaneaxial fans. Axial propellers also provide more performance for a given diameter. These large load banks require more airflow and higher pressures than smaller units. For this application, Axial fans supply 1.7 inches WC static pressure

68179d65be22ee500d53ff54 Card 2

product image
Transformer Cooling Fan

Transformer cooling fans are sturdy, weatherproof fans for accelerating the cooling process in oil-cooled electrical transformers. They circulate air around the exterior of the transformer's radiator as oil works it way through the inside to dissipate heat and reduce the operating temperature of the transformer. Vayuvents Transformer cooling fans are sturdy, weatherproof fans for accelerating the cooling process in oil-cooled electrical transformers. They circulate air around the exterior of the transformer's radiator as oil works it way through the inside to dissipate heat and reduce the operating temperature of the transformer. These fans have a motor that rotates the fan blades to create airflow and a guard that helps protect the blades from damage and prevent injuries from accidental contact. They are typically used outdoors where most oil-cooled transformers are located.

68179d65be22ee500d53ff54 Card 2

product image
welding fume extractor

vayuvents top leading Welding Fume Extractor manufacturer in India. our Portable Welding Fume Extractor with suction arm to collect dust particles and fumes from welding process. vayuventsFume Extractor are manufactured as per the accepted quality standards. Extraction done by using 360 degree rotatable suction arm assures extract the fume easily from the welding process. Assure worker Good health and safety of human resources by removing welding smoke. Additionally, portable Welding Fume Extractor keeps product and production machines contaminant free. We give the time delivery of Portable Welding Fume Extractor at given time frame. vayuventsWelding Fume Extractor Design: vayuvents welding fume extractor is manufactured for heavy duty industrial use to capture the fume at source. Unit attached with a portable wheels frame to move wherever fume extraction is required. Fume extractor consist of 4 stage filtration with modern electrostatic filtration system. This electrostatic filtration requires periodic cleaning only. The Extractor Features four stage filtration and purification. The articulated arm with suction hood is self supporting and quickly positioned at the source of fume emission. System controlled by a control panel operated at 415 V / 50 Hz. Suitable for continuous working without any trouble. CE approved / IP 55 protection induction motor for energy efficiency. High rate of suction airflow and purifying efficiency is more than 99 % and pure air is discharge to workshop atmosphere. Fire proof Spark arrester Electronic panel board for “Filter cleaning stage” warning. Spark arrester, Multi stage filters and Electrostatic filter is easy to clean. Our Mobile Welding Fume Extractor helps to maintain pollution free atmosphere workshop